Cargo Air Shower
Air Shower are classified by the number of particles per cubic meter of air, based on ISO 14644-1 standards.
For example: ISO Class 18 cleanrooms
Filter types: HEPA (99.97% @ 0.3m) or ULPA (99.9995% @ 0.12m
ISO Class0.5 m particles/mTypical Use
ISO 110Nanotech, semiconductor lithography
ISO 2100Advanced microelectronics
ISO 31,000Precision optics, aerospace
ISO 410,000Pharmaceutical filling lines
ISO 5100,000Sterile drug production, LAF hoods
ISO 61,000,000Medical device assembly
ISO 7352,000 (0.5 m only)Compounding pharmacies, electronics
ISO 83,520,000 (0.5 m only)General manufacturing support areas
ISO 935,200,000 (0.5 m only)Comparable to office air
ACH- Air Changes per Hour
ISO 5: 240360 ACH (unidirectional flow)
ISO 6: 90180 ACH
ISO 7: 3060 ACH
ISO 8: 1025 ACH
1. Fan Filter Unit (FFU)
A Fan Filter Unit is a self-contained air filtration system with a built-in fan with filter. It draws in air, filters it, and pushes clean air into the cleanroom. FFUs are modular and often installed in ceilings to create a grid of filtered airflow.
Advantage: Energy-efficient, scalable, and easy to maintain2
2. HEPA & ULPA Filters
These are the heart of cleanroom air purification.
HEPA (High-Efficiency Particulate Air): Captures 99.97% of particles 0.3m
ULPA (Ultra-Low Penetration Air): Captures 99.9995% of particles 0.12m
Applications: Semiconductor, pharma, biotech, aerospace
Key difference: ULPA filters offer higher filtration but with more airflow resistance4
3. Air Shower
An air shower is a decontamination chamber that blasts high-velocity HEPA-filtered air to remove particles from personnel or equipment before entering the cleanroom.
Velocity: 1822 m/s
Cycle time: 1530 seconds
Construction: SS304/316 with interlocking doors
Purpose: Prevents contaminants from entering controlled zones6
4. Laminar Airflow Unit
These units provide a unidirectional flow of clean air either horizontal or vertical across the work surface.
Use: Sterility testing, tissue culture, microelectronics
Airflow: 0.30.6 m/s
Filter: HEPA/ULPA
Types: Benchtop, floor-mounted, ceiling-suspended8
5. Dispensing Booth (Sampling/Weighing Booth)
Also known as reverse laminar flow booths, these are used for safe handling of powders and chemicals.
Airflow: Downward laminar flow with recirculation
Filtration: 3-stage (Pre, Intermediate, HEPA)
Purpose: Protects operator, product, and environment during weighing or sampling10
6. Pass Box (Static & Dynamic)
Used to transfer materials between rooms without compromising cleanliness.
Static Pass Box: No airflow; used between two clean zones
Dynamic Pass Box: Has HEPA-filtered airflow; used between clean and non-clean areas
Features: UV light, electromagnetic interlocks, SS304/316 construction12
7. SS Fabricated Equipment
These include garment cabinets, trolleys, sinks, lockers, benches, and more all made from stainless steel (SS304/316) to ensure corrosion resistance and easy cleaning.
Use: Change rooms, labs, production areas
Design: GMP-compliant, smooth welds, minimal joints
Examples: Cross-over benches, shoe racks, apron cabinets, SS tables14
Product Parameters
|
Model |
Standard Cargo Air Shower 1 |
Standard Cargo Air Shower 2 |
|
External Dimensions (mm) |
W3000D1500H2180 |
W3000D2000H2180 |
|
Air Shower Area Dimensions (mm) |
W1500D1360H1980 |
W1500D1860H1980 |
|
Air Velocity |
18-22m/s |
|
|
Number of Nozzles |
18 |
24 |
|
Number of Fans |
2 |
|
|
Air Shower Duration |
Factory set at 10s, adjustable from 10-99s |
|
|
Material |
High-quality cold-rolled steel, electrostatic spray coating, stainless steel doors, stainless steel floor, stainless steel interior walls |
|
|
Interlocking Mechanism |
Normally electronically interlocked, only one door can be opened at a time; both doors locked during air shower |
|
|
Power Supply |
380V, 50Hz, Three-phase |
|
|
Fan Power |
1.5KW |
|
|
Capacity |
1-2 Persons |
2-4 Persons |
Note: Custom sizes available upon request.
|
Model |
FST-2300-2 |
FST-2300-3 |
|
External Dimensions (mm) |
W2300D2000H2280 |
W2300D3000H2280 |
|
Air Shower Area Dimensions (mm) |
W1500D2000H1980 |
W1500D3000H1980 |
|
Air Velocity |
18-22m/s |
|
|
Number of Nozzles |
24 |
36 |
|
Number of Fans |
4 |
|
|
Air Shower Duration |
Factory set at 10s, adjustable from 10-99s |
|
|
Material |
High-quality cold-rolled steel, electrostatic spray coating |
|
|
Power Supply |
380V, 50Hz, Three-phase |
|
|
Model |
FST-2000-2 |
FST-2000-3 |
|
External Dimensions (mm) |
W2000D2000H2180 |
W2000D3000H2180 |
|
Air Shower Area Dimensions (mm) |
W1200D2000H1980 |
W1200D3000H1980 |
|
Air Velocity |
18-22m/s |
|
|
Number of Nozzles |
24 |
36 |
|
Number of Fans |
4 |
6 |
|
Air Shower Duration |
Factory set at 10s, adjustable from 10-99s |
|
|
Material |
High-quality cold-rolled steel, electrostatic spray coating, stainless steel doors |
|
|
Automatic Door Mechanism |
2 sets |
2 sets of door control |
|
Power Supply |
380V, 50Hz, Three-phase |
|
|
Fan Power |
3KW |
4.5KW |
![]() |

Price:
Price 750000.0 INR / Unit
Minimum Order Quantity : 1 Unit
Material : Others, PVC
Opening Pattern : Horizontal
Insulation : Exterior, Interior
Color : Different Available