FFU-FanFilterUnit
GF24AC-Technical Data Sheet
SN |
Items |
Specifications |
|
1 |
Dimensions(mm) |
1175*1175*180 |
|
2 |
Weight(kg) |
16 |
|
3 |
Noise(dB) |
60 |
|
4 |
(1)TotalStaticPressure(Pa) |
190 |
|
5 |
Material |
Casing |
GalvanizedAluminum |
6 |
Impeller |
Steel-AluminumAlloy |
|
7 |
(2)OperatingAirSpeedwithfilter(m/s) |
0.45 |
|
8 |
MaximumAirVolumewithoutfilter(CMH) |
1300 |
|
9 |
WorkingAirVolumewithfilter(CMH) |
Low |
850 |
10 |
Medium |
950 |
|
11 |
High |
1050 |
|
12 |
Motor |
Power(W) |
190 |
13 |
MaxRPM |
1050 |
|
14 |
Type |
ACInductionMotor |
|
15 |
EfficiencyClass |
IE2 |
|
16 |
(3)ControlMode |
SingleControl |
|
17 |
(4)StartMode |
DirectSwitchStart |
|
18 |
SafeOperatingVoltage |
200V-240V |
|
19 |
SafeOperatingTemperature(C) |
<55 |
|
20 |
(5)AverageDailyPowerConsumption(kWh) |
3.84 |
Explanation
(1)Total Static Pressure: Indicates the total pressure that the FFU can provide under working conditions, including systemresistance.
(2)OperatingAirSpeedwithfilter:TheairflowspeedoftheFFUafterthefilterisinstalled.
(3)ControlModes:
SingleControl:EachFFUoperatesindependently,suitableforsmall-scalesystems.
*Group Control: Multiple FFUs operate in unison, suitable for large-scale cleanrooms, improving managementefficiency.
(4)StartupModes:
DirectSwitchStart:Manuallyturnon/off,eachFFUoperatesindependently.
*Software Automatic Control Start: After connecting the FFU to the control panel, the control panel can be used to setautomaticstart/stopparameters.
*ControlPanelStart:AfterconnectingtheFFUtothecontrolpanel,itcanbemanuallystartedviathecontrolpanel.
*Mentioning Group Control / Control Panel / Automatic / Remote start means that this product supports BA/FCMS automaticcontrolandrequiresanadditionalcontrolsystempurchase.
Price: